Static-control flooring is a grounded resin floor that bleeds static away from people and equipment before it can damage sensitive electronics. We install it and test it on site before turnover.
ESD floors use a conductive or static-dissipative epoxy tied to building ground. When someone walks across the floor, charge drains away instead of building up and jumping to a circuit board, server or test bench.
The floor is one part of your static-control program, alongside grounding straps, footwear and procedures. We coordinate grounding points with your electrical team, install the system your spec calls for and test resistance on site before we hand it over.
Legacy Industrial Coatings installs commercial and industrial epoxy flooring, polished concrete and floor coatings from Plano, Texas, across Dallas–Fort Worth, all of Texas and nationwide. See our commercial and industrial epoxy flooring and polished concrete pages.
Serving Dallas, Fort Worth, Plano, Frisco, McKinney, Richardson, Carrollton, Lewisville and the rest of North Texas, plus Houston, Austin, San Antonio and projects across Texas and nationwide.
We install the type your spec or ESD program calls for, chosen around the equipment in the room.
Ground connections are planned with your electrical scope so the floor actually drains charge.
We test resistance on site against your project spec and document the results.
A durable epoxy surface that stands up to carts and foot traffic and cleans easily.
We tell you which cleaners to use, since ordinary wax can stop the floor from working.


Specs & Data Sheets
For data halls, electrical rooms and electronics lines we install Sherwin-Williams Resuflor static-control flooring. System overviews, application instructions and guide specs are below.
A nominal 20 mil static-dissipative epoxy and urethane system. Per the manufacturer, it tests at 1×10⁵ to 1×10⁹ ohms under ANSI/ESD S20.20 with body voltage under 100 volts.
A thin-mil static-control epoxy topcoat with a stipple finish. Conductive over a conductive primer, static-dissipative over a standard epoxy primer.
A high-gloss, static-dissipative flake floor: vinyl chips in an epoxy base, sealed with an abrasion-resistant polyurethane.
FAQ
Electronics manufacturing, assembly and test areas, electrical and UPS rooms, data center spaces, aerospace shops and some pharmaceutical areas. Anywhere a static spark could damage parts or equipment. If you are unsure, we can review your spec.
No. Flooring is one piece of a static-control program that also includes personnel grounding, procedures and regular checks. We build and test the floor to your spec so it does its part.
Only if the manufacturer confirms it is compatible. Many waxes and finishes leave an insulating film that keeps the floor from draining static. We hand over approved care guidance at closeout.
No. The owner and design team decide based on the equipment and the facility's static-control plan. Some facilities use ESD floors in electrical and UPS rooms and standard epoxy elsewhere.
It depends on square footage, slab prep and repairs, conductive or dissipative system, grounding work and how the install is phased around your operation. We return a full bid within 24 hours of receiving plans, so send yours or request a site walk.
Send plans or a scope. Site walk within 1–3 business days; full bid within 24 hours of receiving plans.
Tell us about your project and we'll follow up within one business day.
Prefer to talk now? Call (214) 305-6516 or